MENDOTA GAS DIRECT VENT FIREPLACE
with
Premium Texture Fiber Logs Combustion System
Model DXV-35 DT3-PF2-LX
INSTALLATION & OPERATING INSTRUCTIONS
NO. PF2-LX-0113
WARNING
If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal
injury or loss of life.
CAUTION: Keep gasoline and other liquids having flam-
mable vapors away.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control, which has been under water.
AVERTISSEMENT. Quiconque ne respecte pas à la lettre
les instructions dans la présente notice risque de dé-
clencher un incendie ou une explosion entraînant des
dommages, des blessures ou la mort.
ATTENTION. Garder l’essence ou autres liquides produi-
sant des vapeurs inflammables loin del’appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
Ne pas tenter d’allumer d’appareil.
Ne touchez à aucun interrupteur; ne pas vous servir
des téléphones se trouvant dans le bâtiment.
Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du
fournisseur.
Si vous ne pouvez rejoindre le fournisseur, appelez
le service des incendies.
N’utilisez pas cet appareil s’il a été plongé dans l’eau,
même partiellement. Faites inspecter l’appareil par un
technicien qualifiéet remplacez toute partie du système
de contrôle et toute commande qui ont été plongés dans
l’eau.
AVERTISSEMENT : Une installation, un réglage, une modifi-
cation, une réparation ou un entretien mal effectué peut cau-
ser des dommages matériels ou des blessures. Voir la notice
de l'utilisateur quiaccompgne l’appareil. Pour de l’aide oueds
renseignements supplémentaires, consultez un installateur,
un technicien agréé ou le fournisseur de gaz.
WARNING: Improper installation, adjustment, alteration,
service or maintenance can cause injury or property damage.
Refer to this manual. For assistance or additional infor-
mation consult a qualified installer, service agency or the gas
supplier.
Vedere la pagina 0
1 2 3 4 5 6 ... 64 65

Sommario

Pagina 1 - Model DXV-35 DT3-PF2-LX

MENDOTA GAS DIRECT VENT FIREPLACE with Premium Texture Fiber Logs Combustion System Model DXV-35 DT3-PF2-LX INSTALLATION & OPERATING INSTRUCTIO

Pagina 2

9 GENERAL INFORMATION Your Mendota Gas Fireplace has a state-of-the-art co-axial direct vent, sealed combustion system. This advanced, highly effic

Pagina 3

10 VENT OPTIONS DISCUSSION This Mendota Fireplace can be vented using AMERIVENT, DURAVENT, SELKIRK METALBESTOS, SECURITY CHIMNEY and ICC brands of c

Pagina 4

11 GAS SUPPLY REQUIREMENTS Correct gas pressure and proper gas supply line sizing is imperative to the successful performance of your Mendota gas fi

Pagina 5

12 GAS PRESSURE REQUIREMENTS A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLIANCES CAN BE IMPROPER GAS PRESSURE! Problems such as changes in flame

Pagina 6

13 EXTERIOR VENT LOCATIONS AND RESTRICTIONS Figure 2: Exterior Vent Locations ALL MEASUREMENTS GIVEN ARE FROM THE CENTER LINE OF VENT CAP ∨ - Vent

Pagina 7

14 GENERAL FLUE VENTING INSTRUCTIONS The Mendota Fireplace must be vented using Amerivent, Duravent, Selkirk Metalbestos, Security Chimney or ICC Br

Pagina 8

15 GENERAL INSTALLATION INSTRUCTIONS CAUTION: Each installation must conform to all local, state and national codes. Refer to the national fuel gas

Pagina 9 - CAUTION

16 outage, turn off the burners for 1 hour and allow the fireplace to cool down. Consecutive 1-1/2 hour burn and 1 hour cool down cycles are allowed

Pagina 10

17 TOP FLUE VENTING COMPONENTS ITEM DESCRIPTION 1 12" VENT STACK 1 24" VENT STACK 1 36" VENT STACK 1 48" VENT STACK 2 90ºGALVA

Pagina 11 - TOP VENTING

18 FLUE VENTING ALLOWANCE CHART NOTE: FOR LP GAS & HIGH ALTITUDE, SEE PG. 19 NOTE: FOR LPG AND HIGH ALTITUDEAPPLICATIONS, SEE PAGE 19. NOTE: 1

Pagina 12

In the Commonwealth of Massachusetts: • Installation must be performed by a licensed plumber or gas fitter; • A CO

Pagina 13

19 L.P. GAS MINIMUM HEIGHT HORIZONTAL TERMINATION For L.P. gas and high altitude installations (above 4,000 ft.), 45° elbows must be used in plac

Pagina 14 - ∧ - Air Supply Inlet

20 MINIMUM RISE THROUGH-THE-WALL VENTING: The minimum vertical rise for vent installation through the wall is 16 1/4" from the top of the firep

Pagina 15 - WARNING

21 VENTING COMPONENTS LIST NOTE: ALL PART NUMBERS LISTED ABOVE APPLY TO SIMPSON DURAVENT COMPONENTS ONLY. MENDOTA # DESCRIPTION45-01-00186 7&quo

Pagina 16

22 ELEVATED VERTICAL RISE THROUGH-THE-WALL VENTING The required MINIMUM vertical rise is 48 in. when used with a maximum horizontal run of 12 ft. F

Pagina 17 - 85-03-00458

23 VERTICAL THROUGH-THE-ROOF VENTING The maximum vertical run of vent pipe is 55 ft. from the top of the fireplace. The fireplace will support a ru

Pagina 18

24 2.) PULL3.) ROTATE4.) RELEASE1.) INSERTDOOR REMOVAL AND REPLACEMENT CAUTION: Do not operate the appliance with glass removed, cracked or broken.

Pagina 19 - APPLICATIONS, SEE PAGE 19

25 GLASS FRAME ASSEMBLY REPAIR AND REPLACEMENT TO REPLACE DAMAGED GLASS 1. Using a 1/8” drill bit, drill through 3 rivets on each side of glass f

Pagina 20 - 85-03-00531

26 DXV-35 DT3 DEEP TIMBER LOG SET INSTALLATION INSTRUCTIONS FOLLOW EACH STEP DEPICTED IN THE DIAGRAMS, BELOW, TO INSTALL THE LOG SET. CAUTION: LOGS

Pagina 21

LOG# 1 PLACE LOG #1 (REAR LOG) ON REAR SHELF BEHIND REAR BURNER. SLIDE LOG TO RIGHT UNTIL LOG TOUCHES RIGHT SIDE BRICK PANEL. PUSH LOG BACK SO IT TOUC

Pagina 22

LOG #2 LOG #2 LOG #2 (MID EMBER BED) SITS BETWEEN REAR AND FRONT BURNER, FLAT DOWN ON THE SURFACE OF THE BURNER AIRBOX. ADJUST POSITION OF FRONT AND R

Pagina 23

2 DXV35 DT3 FEATURES - QUICK REFERENCE INFORMATION EXTERNAL DIMENSIONS: 35-7/8” Wide X 31-1/2” High X 15-1/2” Deep MINIMUM FRAMING DIMENSIONS: 37-1

Pagina 24

LOG #2 LOG# 1 LOG# 3 PLACE LOG #3 (LEFT LOG) ON TOP OF THE RECTANGLE AIR SHUTTER BOX ON THE LEFT SIDE. LOG #3 HAS A RECTANGULAR NOTCH ON ITS BOTTOM SI

Pagina 25 - DETAIL A

LOG #4 LOG #4 (RIGHT LOG) HAS A HOLE FOR THE PIN ON LOG #2. INSERT PIN IN LOG #2 INTO HOLE IN LOG #4. SET RIGHT END OF LOG #4 ON TOP OF THE FIRST GRAT

Pagina 26 - FLAT FORM

LOG #2 LOG# 1 LOG# 3 LOG# 4 LOG# 5 LOG #5 (LEFT TOP LOG) SITS ON THE LEFT SHOULDER OF LOG #1 AND ITS TWO BRANCHES SIT ON TOP OF LOG #2 AND LOG #3. LOG

Pagina 27

LOG #6 (RIGHT TOP LOG) SITS ON TOP OF LOG #1 USING THE PIN THAT IS ON THE RIGHT SIDE OF LOG #1. LOG #6 HAS A HOLE IN ITS BACK-SIDE TO MATE WITH THIS P

Pagina 28

LOG# 4 LOG# 7 LOG# 7 LOG #7 REST ON TOP OF THE FRONT BURNER’S REAR VISIBLE EDGE AND ON TOP OF LOG #4. THIS LOG IS DESIGNED TO HIDE THE PILOT LIGHT. P

Pagina 29

LOG# 2 LOG# 8 LOG# 8 PLACE LOG #8 ( LEFT FRONT TWIG) IN THE POSTION SHOWN HERE. LOG #8 SITS ON TOP OF LOG #2 AND RESTS AGAINST THE GRATE BAR (2ND FROM

Pagina 30

LOG# 9 LOG #9 (RIGHT FRONT CHUNK) IS TO BE PLACED AT A SEVERE ANGLE AGAINST THE HORIZONTAL GRATE BAR AND FLOATING OVER THE FRONT BURNER PORTS. THE POS

Pagina 31 - ON TOP OF LOG #2, HERE

COMPLETED LOG SET ASSEMBLY

Pagina 32

37 The following Check Off Lists must be completed prior to final operation of the Fireplace, or manufac-turer's warranty and liabilities will

Pagina 33

38 BEFORE YOU BEGIN Read this entire manual before you use your new fireplace (especially the section “Safety Precautions” on page 2). Failure to

Pagina 34

3 TABLE OF CONTENTS FOR YOUR SAFETY READ BEFORE LIGHTING ...

Pagina 35

39 REMOTE TRANSMITTER OPERATING INSTRUCTIONS TO TURN ON THE APPLIANCE: 1. Press the ON/OFF button. The transmitter display will show all active

Pagina 36

40 TEMPERATURE INDICATOR (oF or oC) 1. Press the ON/OFF Key and Turn Off the Fireplace. 2. Simultaneously, Press both the MODE Key and the Thermosta

Pagina 37 - COMPLETED LOG SET ASSEMBLY

41 “FIRST TIME” PILOT LIGHTING INSTRUCTIONS IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" in the Installation Manual have

Pagina 38

42 ATTENTION! • The transmitter and receiver are RADIO FREQUENCY DEVICES. • Turn off the main gas supply of the appliance during installation or

Pagina 39 - ON SMART

43 Backup Batteries Backup Batteries are to be installed in the Battery Pack located on the right side of the Courtesy Panel beneath the glass frame

Pagina 40 - TO TURN ON THE APPLIANCE:

44 BLOWER OPERATION AND WIRING WARNING: The Electrical Junction box within this appliance must be connected to a grounded LIVE power circuit. No swi

Pagina 41

45 TROUBLE SHOOTING MENDOTA GAS DXV FIREPLACE SYMPTOM PROBABLE CAUSES CORRECTIVE ACTION 1. Thin black coating (soot) forms on viewing glass. A.

Pagina 42 - REMOTE TRANSMITTER

46 CUSTOMER INFORMATION AND TROUBLE-SHOOTING MAXIMUM ALLOWABLE SURFACE TEMPERATURE Mendota Fireplaces comply with UL Standards for maximum surface t

Pagina 43 - ATTENTION!

47 MAINTENANCE 1. ANNUAL MAINTENANCE OF MENDOTA UNITS IS REQUIRED. The following procedures must be performed each year by a Mendota approved serv

Pagina 44

48 WIRING SCHEMATICS Note: The DXV35-DT3-LX ignition system utilizes Transformed DC power for normal ignition functions. In the event of a power out

Pagina 45

4 SPECIFICATIONS MODEL DXV-35 DT3 INPUT RATES (Btu/Hr) High Fire - Adjustable to - Low Fire NAT. GAS 33,000 10,000 LP GAS

Pagina 46

49 NATURAL TO LP GAS CONVERSION INSTRUCTIONS Kit # HA-30-00507 Mendota Model DXV35 DT3 This conversion kit shall be installed by a qualified servic

Pagina 47

50 5. Using a ½” deep well socket wrench, remove Front and Rear Orifices. 6. Thread a new 3/64” drilled orifice to both Front and Rear Orifice mo

Pagina 48

51 10. Before reinstalling burners, loosen the screw that secures the rotary air shutter on the Front Burner. Rotate the air shutter open to ¼” min

Pagina 49

52 INSTALLING THE LP PRESSURE REGULATOR WARNING: READ AND UNDERSTAND ALL INSTRUCTIONS PACKAGED WITH LP PRESSURE REGULATOR BODY BEFORE YOU ATTEMPT TH

Pagina 50 - REAR BURNER

53 INLET TAP OUTLET TAP LP GAS PRESSURE REQUIREMENTS Inlet and manifold gas pressure checking taps are located on gas valve. These ports are only ac

Pagina 51 - DETAIL C

54 WARNING DO NOT PROCEED WITH OPERATION OF THIS FIREPLACE UNLESS BURNER "CYCLES" ON/OFF WITHOUT DELAYS! CHECKING FOR NORMAL BURNER (S) I

Pagina 52 - -1/4" MINIMUM

55 REPLACEMENT PARTS MENDOTA GAS DXV-35 DT3 FIREPLACE PART NO DESCRIPTION PART NO DESCRIPTION 65-02-00103 TADPOLE GLASS GASKET (106”) 05-04

Pagina 53

56 MENDOTA DESIGNER FRONTS INSTALLATION INFORMATION The following Designer Fronts are available for the DXV-35 Fireplace: 1. Andover, Bentley Arc

Pagina 54 - 1" MIN

57 HEARTH PAD SURFACE MUST BE FLUSH WITH FIREPLACE BOTTOMIF INSTALLING THE WELLINGTON!!HEARTH PADSURFACEInformation specific to the installation of

Pagina 55

58 RATING LABEL REPRESENTATION DXV35 DT3

Pagina 57 - FIREPLACE’S FACEPLATE

59 THIS PAGE LEFT BLANK INTENTIONALLY

Pagina 58 - Figure 10

60 THIS PAGE LEFT BLANK INTENTIONALLY

Pagina 59 - DXV35 DT3

61 MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM As a part of Mendota's on-going program of customer satisfaction, this Form ver

Pagina 60

62 TAPE SHUT ------------------------------------------------------------------------------------------------------------------

Pagina 61

63 MENDOTA EXTENDED PROTECTION AND LIMITED WARRANTY MENDOTA DXV35 DIRECT VENT FIREPLACE INSERT Mendota Division of Johnson Gas Appliance Company,

Pagina 62

Johnson Gas Appliance Company 520 E Avenue N.W. - Cedar Rapids, IA 52405 Mendota Hearth Division

Pagina 63

6 Specific Requirements for the Common Wealth of Massachusetts The information in this section applies to all installations performed in the Common

Pagina 64

7 SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the appliance. FAILURE TO FOLLOW these instruc-tions

Pagina 65

8 CONGRATULATIONS You are the owner of a world-class heat producing gas direct vent sealed combustion fireplace. This elegant, highly efficient Fire