Part #85-03-00856 INSTALLATION & OPERATING INSTRUCTIONS FullView Direct Vent Gas Fireplace Insert Heater With Premium Texture Fiber Logs C
9 CONGRATULATIONS You are the owner of a world-class heat producing gas direct vent sealed combustion fireplace. This elegant, highly efficient Firep
10 GENERAL INFORMATION Your Mendota Gas Fireplace Insert has a state-of-the-art direct vent, sealed combustion system. This advanced, highly effic
11 LOCATIONS OF FUNCTIONAL COMPONENTS ACCENT LIGHT DIMMER SWITCHACCENT LIGHT DIMMER SWITCHRECEIVERMAIN GAS VALVEIPI CONTROL MODULEREAR BURNER SOLENO
12 E-FV33i OVERALL DIMENSIONS 5 1/2291.25015 5/8Surround Faceto Gas LineEntry Hole Center11 7/8To Gas LineEntry Hole Center7 7/81 7/8SURROUND/FACEP
13 8.016" MIN.FROM GLASS FRAME EDGETO PERPENDICULAR SIDE WALL-A-12" MINFROM TOP EDGE OF TOPCONVECTION AIR OPENINGTO BOTTOM OF 8" DEEP
14 INSTALLATION INSTRUCTIONS CAUTION: Each installation must conform to all local, state and national codes. Refer to the national fuel gas code an
15 FLUE VENTING The E-FV33i Insert must be vented vertically to the outside and must use the Mendota Co-Linear flexible ducting system. The minimum v
16 Chimney Flashing and cap (See FIGURE BELOW) The vent kits include a trim-able flashing. Measure, trim and shape flashing to fit the existing flue
17 14. Remove the Vent Adapter by removing two 5/16” Hex Bolts and sliding Vent Adapter towards rear of Insert. 15. Tightly secure 3” and 4” flex
18 18. You are now ready to hook up the Insert to gas supply. Be sure gas plumbing instructions and all state and local codes have been carefully
1 In the Commonwealth of Massachusetts: Installation must be performed by a licensed plumber or gas fitter; A CO detector shall be installed in
19 RAISED HEARTH SPECIFICATIONS In most installations, a 16" non-combustible protector is required in front of the unit’s glass door surfac
20 GAS SUPPLY REQUIREMENTS NOTE: IF INSERT IS TO BE OPERATED WITH LP GAS, SEE PAGE 34 BEFORE PROCEEDING. CORRECT GAS PRESSURE AND PROPER GAS SUPPL
21 GAS PRESSURE REQUIREMENTS One major cause of operating problems with gas appliances can be improper gas pressure! Such problems as changes in flam
22 HIGH ALTITUDE INSTALLATIONS For installations from 610-1370 meters (2000-4500 ft.) the orifice sizes (DMS) for natural gas are #46R/#49F and for
23 INSTALLATION CHECK OFF LIST The following check list must be completed prior to initial lighting of the Fireplace Insert, or manufacturer's
24 2.) PULL3.) ROTATE4.) RELEASE1.) INSERTDOOR REMOVAL AND REPLACEMENT CAUTION: Do not operate the appliance with glass removed, cracked or broken
25 E-FV33i LOG SET INSTALLATION INSTRUCTIONS FOLLOW EACH STEP DEPICTED IN THE DIAGRAMS, BELOW, TO INSTALL THE LOG SET. CAUTION: LOGS ARE FRAGILE, HAN
PLACELOG#1(REARLOG) ONREARSHELFBEHINDREARBURNER.SLIDELOGTORIGHTUNTIL LOG TOUCHES RIGHTLOG# 1UNTILLOGTOUCHESRIGHTSIDEBRICKPANEL.PU
LOG#2(MIDEMBERBED)SITSBETWEENREARANDFRONTBURNER,FLATDOWNONTHESURFACEOFTHEBURNERAIRBOX.ADJUSTPOSITIONOFFRONTANDREARBURNERSIF
PLACELOG#3(LEFTLOG)ONTOPOFTHERECTANGLEAIRSHUTTERBOXONTHELEFTSIDE.LOG#3HASARECTANGULARNOTCHONITSBOTTOMSIDETHATALLOWS THE LO
2 Due to high temperature, the appliance should be LOCATED out of traffic areas and away from furniture and draperies. En raison des températures él
LOG#4(RIGHTLOG)HASAHOLEFORTHEPINONLOG#2.INSERTPININLOG#2INTOHOLEINLOG#4.SETRIGHTENDOFLOG#4ONTOPOFTHEFIRSTGRATELOG#4
LOG#5(LEFTTOPLOG)SITSONTHELEFTSHOULDEROFLOG#1ANDITSTWOBRANCHESSITONTOPOFLOG#2ANDLOG#3.LOG#5HASAHOLETHATALIGNSWITHTHE
LOG#6(RIGHTTOPLOG)SITSONTOPOFLOG#1USINGTHEPINTHATISONTHERIGHTSIDEOFLOG#1.LOG#6HASAHOLEINITSBACK‐SIDETOMATEWITHTHISP
LOG#7LOG#7RESTONTOPOFTHEFRONTBURNER’SREARVISIBLEEDGEANDONTOPOFLOG#4. THISLOGISDESIGNEDTOHIDETHEPILOTLIGHT.PLACETHISLOGS
PLACELOG#8(LEFTFRONTTWIG)INTHEPOSTIONSHOWNHERE.LOG#8SITSONTOPOFLOG#2ANDRESTSAGAINSTTHEGRATEBAR(2NDFROMLEFT).LOG#8ATTEMPTT
LOG#9LOG# 9LOG#9LOG#9(RIGHTFRONTCHUNK)ISTOBEPLACEDATASEVEREANGLEAGAINSTTHEHORIZONTALGRATEBARANDFLOATINGOVERTHEFRONTBURNERPOR
COMPLETEDLOGSETASSEMBLY35
37 75 REMOTE TRANSMITTER OPERATING INSTRUCTIONS TO TURN ON THE APPLIANCE: 1. Press the ON/OFF button. The transmitter display will show all active
36 BEFORE YOU BEGIN Read this entire manual before you use your new fireplace (especially the section “Safety Precautions” on page 7). Failure to f
38 MANUAL BYPASS OF THE REMOTE SYSTEM If the remote transmitter is misplaced or lost, the appliance can be turned on manually by sliding the three p
3 E-FV33i FEATURES - QUICK REFERENCE INFORMATION EXTERNAL DIMENSIONS: 30-3/8” Wide X 18-3/8” High X 15-3/4” Deep GLASS SIZE: NeoCeram Glass with no
39 “FIRST TIME” PILOT LIGHTING INSTRUCTIONS IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" in the Installation Manual have
40 ATTENTION! The transmitter and receiver are RADIO FREQUENCY DEVICES. Placing the receiver in or near metal may severely reduce the signal range.
41 E-FV33i GAS IGNITION SYSTEM WIRING DIAGRAM
42 MAINTENANCE 1. ANNUAL MAINTENANCE OF MENDOTA UNITS IS REQUIRED. The following procedures must be performed each year by a Mendota approved servi
43 MotorizedLP PressureRegulator[10.0-5.5"WC]# 907.012Burner Orifice#65-14-00364[3/64"DRILL]364364LP Pilot Orifice[#977.168]NATURAL TO LP G
44 Use an Alan WrenchTo loosen and removeNG Pilot Orifice. InstallLP Pilot Orifice, TightenDown.Pull Pilot Hood UPand lift UP off the base.WIRE CLIP.
45 11. Before reinstalling burners, loosen the screw that secures the rotary air shutter on the Front Burner. Rotate the air shutter open to ¼” min
46 You must remove the left side Valve Access Panel to replace the pressure regulator. 1. Remove the left-side access panel mounted to the left out
47 LP PRESSURE REGULATOR CONVERSION INSTRUCTIONS WARNING: Failure to position the parts in accordance with these diagrams or failure to use only part
48 LP GAS PRESSURE REQUIREMENTS Inlet and manifold gas pressure checking taps are located on gas valve. These ports are only accessible from the oute
4 TABLE OF CONTENTS SAFETY AND WARNING INFORMATION ...
49 WARNING DO NOT PROCEED WITH OPERATION OF THIS FIREPLACE UNLESS BURNER "CYCLES" ON/OFF WITHOUT DELAYS! CHECKING FOR NORMAL BURNER (S) IG
50 CUSTOMER INFORMATION AND TROUBLE-SHOOTING MAXIMUM ALLOWABLE SURFACE TEMPERATURE Mendota Inserts/Fireplaces comply with UL Standards for maximum
51 BURNER FLAMES ADJUSTMENT- AIR INTAKE DAMPER CONTROLS This appliance is equipped with two Air Intake Adjustment Damper Controls: PRIMARY DAMPER and
52 BURNERS AIR SHUTTER CONTROLS During the initial installation, the Front Burner Rotary Manual Air shutter opening should be checked to make certa
53 71516113914175212108GAS VALVE TRAIN ASSEMBLY REPLACEMENT PARTS LIST E-FV33i VALVE ASSEMBLY COMPONENTS LIST KEY# QTY Part Number Description 1 1 0
54 USE LARGE PLIERS TOBEND DOWN (4) TABSAS SHOWNGLASSGASKETGLASS FRAME ASSEMBLY REPAIR AND REPLACEMENT TO REPLACE DAMAGED GLASS 1. Bend Glass Ret
55 MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM As a part of Mendota's on-going program of customer satisfaction, this Form ver
56 THIS PAGE LEFT BLANK, INTENTIONALLY.
57 TAPE SHUT -------------------------------------------------------------------------------------------------------------------
58 MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY MENDOTA GAS FIREPLACE INSERT MODEL: E-FV33i NAT. & L.P. Mendota Division of Joh
5 GLASS FRAME ASSEMBLY REPAIR AND REPLACEMENT ...
Part #85-03-00856 Johnson Gas Appliance Company 520 E Avenue N.W. - Cedar Rapids, IA 52405 Website: www.johnsongas.com or www.me
6 SPECIFICATIONS MODEL E-FV-33i Natural Gas Propane Gas Input rating (Btu/hr) 0-610 m 31,000 31,000 Minimum input (Btu/hr) 0-610 m 21,00 25
7 Specific Requirements for the Common Wealth of Massachusetts The information in this section applies to all installations performed in the Common W
8 SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the appliance. FAILURE TO FOLLOW these instruc-tions